SAFETY AND PROTECTION IN THE MANAGEMENT OF THE RAILWAY TRACTION
RAYLWAYS| SUBWAYS| TRAMWAYS | TROLLEY-BUS
Tramways short circuit device of the contact line with clamp for throath rails
COMPOSITION:
No. 1 light alloy contact clamp with foldable jaw and screw tightening provided with aluminum torque limiter bound to the active part, length = 1,6 m |
No. 2 insulating sticks in epoxy resin, base and extension, with length 1,5 m each, joinable through press button joint. Base equipped with hand guard and end cap with strengthened joint for the connection to the aluminum pipe. |
Total length of the device 4,6 m |
No. 1 extra-flexible copper cable 50 mm2, length = 6,1 m covered with silicone sheath. |
No. 1 clamp for the connection to rails provided with torque limiter for the tightening of the clamp on rails. |
No. 1 nylon bag with shoulder belt for the transfer. |

Download technical sheet
In accordance to STD IEC 61230
Ref./Conf. STF RFI DMA IM TE SP IFS 003 – Cat. 817/605
Our Mod. CCLC-SDN/50/3-6,1m-LN
Cable sec. mm2 | Icc 0,25s | Icc 0,5s | Icc 1s |
---|---|---|---|
50 | 22,5 kA | 18 kA | 12,7 kA |