SAFETY AND PROTECTION IN THE MANAGEMENT OF THE RAILWAY TRACTION
RAYLWAYS| SUBWAYS| TRAMWAYS | TROLLEY-BUS
Earthing and short circuit mobile device for catenary – contact lines 25 kVac 50 Hz three components
COMPOSITION:
No. 1 light alloy contact clamp with foldable jaw and screw tightening provided with aluminum torque limiter bound to the active part, length 1,6 m. |
No. 2 insulating sticks in epoxy resin in a single piece. Length 1,5 m provided with hand guard and end cap with strengthened joint for the connection to the aluminum pipe. |
Total length of the device: 4,6 m |
No. 1 copper flexible cable, sec. 50 mm2 length = 6,1 m covered with transparent silicone. |
No. 1 clamp for the connection the rail provided with torque limiter for the tightening of the clamp on the rail. |
Optional: – Nylon bag with shoulder belt. |

Download technical sheet
In accordance to STD IEC 61230
Ref./Conf. STF RFI DMA IM TE SP IFS 003 – Cat. 817/605
Our Mod. CCLC-SDN/50/3-6,1 m – LN
Cable sec. mm2 | Icc 0,25s | Icc 0,5s | Icc 1s |
---|---|---|---|
50 | 22,5 kA | 18 kA | 12,7 kA |